Configure eScheduler

Top  Previous  Next

 

Options > System

clip0041

 

Database: Set the default data source

 

Temp Folder: Set the temp folder used to create and copy temporary files to.

 

Debug Mode: Set the flag for logging debug information into log files.

 

 

Options > Service

clip0043

 

Depend on Process: Set dependency between eScheduler Service and a process. When the process terminates the eScheduler service is stopped.

 

Startup wait: Set the eScheduler Service wait time to become active after booting the computer

 

Oracle Host IP address: Set the eScheduler Service Oracle host ip address. This is used to check if oracle is available after a database or network failure. (see tnsnames.ora, e.g. 10.0.0.2)

 

Oracle Port: Set the eScheduler Service Oracle port. This is used to check if oracle is available after a database or network failure. (see tnsnames.ora, e.g. 1521)

 

 

Options > User

clip0044

 

Name: Set name displayed in the email messages that are sent by eScheduler

 

Mailto: Set email address used as reply address for email messages that are sent by eScheduler

 

Tel: Set contact telephone number

 

 

Options > Email

clip0045

 

Server Type: Set the method to send email messages

 

Server/Profile: Set the Microsoft Exchange Profile (requires Collaboration Data Objects) or SMTP server used to send email messages

 

Default Subject: Set the subject displayed in the email messages

 

 

Options > Impromptu

clip0046

 

Default Userclass: Set the Userclass to logon to Impromptu Catalogs

 

Default Password: Set the Userclass password to logon to Impromptu Catalogs

 

Default Retry: Set the default retry rate for tasks that returned an error

 

 

Options > Transformer

clip0047

 

trnsfrmr.exe: Set the location of trnsfrmr.exe

 

ppadmtool.exe: Set the location of ppadmtool.exe to update Powerplay Web Cubes

 

Model Folder: Set the location where the Transformer model (.P??) files will be copied, before eScheduler builds the cube. It is important because by copying the model the original file will not be locked during the build process. Furthermore no categories will be added to the original model.The copy can later be used to overwrite the original model when the new categories need to be used for special categories and alternative drilldown paths.

 

Parameters: Set the Transformer command line parameters

 

CurrentPeriod: Set the period category format to set the current period. The current period will be set to date of cube build - 1 day. It is important to disable "Automatically set the current time period" in Transformer in order to allow eScheduler to set the current period.

 

 

Options > PDF

clip0048

 

Printer: Set the PDF printer

 

Output Folder: Set the output folder used by the PDF printer

 

Install: Start the WIN2PDF setup wizard

 

Configure: Configure WIN2PDF to use it with eScheduler

 

 

 

Options > Reportnet

clip0052

 

 

Endpoint URL: Set the default url of the Reportnet gateway

 

Username: Set the username to access Reportnet

 

Password: Set the password to access Reportnet

 

Namespace: Set the Reportnet namespace

 

Max. Mail Filesize: Set the maximum filesize in megabytes of the Reportnet email attachment.

Files larger than the set value are not send but saved in the temporary folder.